TC5 THERMOCOUPLE FOR USE IN THE PLASTICS INDUSTRY
• Max. temperature limit: – 40 … + 250° C (see table for thermocouple cable used)
• Reference tolerances:
Standards IEC 584.2 class 2: for type J, K: ± 2.5° C (- 40 … + 333° C)
• AISI 303 stainless steel tip
• Mount threading adjustment spring: ø 8mm, length 300mm.
• Cable to DIN standard
THERMOCOUPLE FOR USE IN THE PLASTICS INDUSTRY GEFRAN MODEL TC5-B-1-J-5-Q-I-B-3 040X000X00015XA
SINGLE ISOLATED ELEMENT
ELEMENT TYPE Fe – Cu/Ni
CABLE (TO DIN STANDARD) TTS TYPE
MATERIAL TYPE AISI 303
DIAMETER 6mm
MOUNT THREADING G1/4
MOUNT MATERIAL GALVANIZED CARBON STEEL
TEMPERATURE LIMITS -40…+250°C
CABLE LENGTH 40cm
IMMERSION LENGTH 15 mm
MODEL WITH BAYONET SCREW